ISO 9001 · ISO 14001 · ISO 45001 · CE CPR EN 50575 · TÜV (PV) · UL · SAA export@voltcorecable.com +86 139 0658 4505 Downloads

The complete Voltcore cable range

Sixty-seven constructions across sixteen families — every one with published reference dimensions, layer-by-layer construction and the standard it is built to.

If the construction you need is not here, it is probably a variant we already run. Send the standard and we will confirm.

Power Cable

Voltcore Cable makes copper and aluminium power cable to IEC 60502-1 and IEC 60502-2, armoured, unscreened or screened, shipped from Shanghai in 15-25 working days.

YJV-0.6-1kV YJV XLPE Insulated PVC Sheathed Power Cable Copper conductor, XLPE insulation, PVC oversheath: the default 0.6/1 kV distribution build for indoor tray, conduit and duct routes. View specification → YJY-0.6-1kV YJY XLPE Insulated PE Sheathed Low Smoke Power Cable A polyethylene oversheath instead of PVC: halogen-free, near-zero water transmission, and available as a tested LSZH construction. View specification → YJV22-0.6-1kV YJV22 Steel Tape Armoured XLPE Power Cable Double galvanised steel tape under a PVC jacket: built to take the radial pressure of backfill and excavation tools, not the pull of a winch. View specification → YJV32-0.6-1kV YJV32 Steel Wire Armoured XLPE Power Cable Round galvanised steel wire armour that carries the cable's own weight — specified where the route pulls, drops or hangs. View specification → MV-YJV-6-10kV YJV 6/10 kV Medium Voltage XLPE Power Cable Three-layer screened construction at 6/10 kV: the default primary distribution cable for industrial plants and utility feeders. View specification → MV-YJV22-8.7-15kV YJV22 8.7/15 kV Armoured Medium Voltage Cable 4.5 mm insulation and steel tape armour: the specification for 15 kV feeders laid directly into open ground. View specification → VV-0.6-1kV VV PVC Insulated PVC Sheathed Power Cable Both layers in PVC: the economical 0.6/1 kV build for circuits whose load is known, stable and well inside a 70 °C conductor limit. View specification → VV22-0.6-1kV VV22 PVC Insulated Steel Tape Armoured Cable Armoured burial protection at PVC cost — the right answer when the route needs armour but the load does not need 90 °C insulation. View specification →

All Power Cable →

Control & Instrumentation Cable

Screened, twisted and alloy-conductor cable for control panels, VFD drives, 4–20 mA loops and temperature measurement loops.

All Control & Instrumentation Cable →

Special Cable

Fire resistant, LSZH, mining trailing, marine and offshore constructions — with the test reports that let a consultant sign them off.

NH-YJV-0.6/1kV NH-YJV Mica Tape Fire Resistant XLPE Cable Circuit integrity to 750 °C for 90 minutes without changing the XLPE installation method you already use. View specification → BTTZ-500V/750V BTTZ Mineral Insulated Copper Sheathed Cable Magnesium oxide inside a copper tube: no organic material in the cable to burn. View specification → WDZ-YJY-0.6/1kV WDZ-YJY LSZH Power Cable Zero halogen acid gas and 60% light transmittance with XLPE ampacity unchanged. View specification → ZH-BYJ-450/750V HFFR / ZH Halogen Free Building Cable Single-core building wire and 0.6/1 kV power cable on one halogen-free compound platform. View specification → MVV-0.66/1.14kV MVV / MVV22 Mining Power Cable Fixed-installation mine power cable with the earth core sized by MT 818 rather than by guesswork. View specification → MYP-0.66/1.14kV MY / MYP Flexible Mining Trailing Cable Built to be dragged over rock: fine-strand conductor, EPR insulation and a tear-resistant rubber sheath. View specification → CEFR-0.6/1kV CEF / CEFR Shipboard Power Cable Tinned copper, EPR or XLPE insulation and a compound selected for salt, oil and vibration. View specification → CKYJP-0.6/1kV Marine Flame Retardant Low Smoke Control Cable Screened control and instrumentation cable that keeps signal integrity beside power runs. View specification → PV1-F/H1Z2Z2-K-1.5-35 PV1-F / H1Z2Z2-K Solar Photovoltaic Cable Two independent cross-linked walls, tinned Class 5 conductor, and a 25-year outdoor rating that EN 50618 actually tests for. View specification → PV-STRING-1500V DC 1500 V Solar String Cable String and home-run cable for 1500 V blocks, supplied cut to the length your array layout actually needs. View specification → YC-450/750V YC Heavy-Duty Rubber-Sheathed Flexible Cable 450/750 V The heavy-duty rubber sheathed cable that Chinese plant drawings specify for mobile equipment and site power. View specification → H07RN-F-450/750V H07RN-F Harmonised Rubber Cable The harmonised 450/750 V rubber cable European enquiries write by name, produced to HD 22 and CE marked. View specification →

All Special Cable →

Overhead Conductor & Building Wire

From AAC and ACSR overhead conductor priced against metal index, to BV, BVR and UL THHN/THWN-2 building wire for panel-level distribution.

All Overhead Conductor & Building Wire →

Every construction, alphabetically

Not sure which one? Send the application instead

Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.

  • Engineer-reviewed before pricing
  • Reference drawings issued with the quotation
  • Free sample up to free sample up to 5 m

or export@voltcorecable.com · WhatsApp

Tell us the load, the route and the standard — we will come back with a sized quotation

RFQs are answered by an application engineer first. Typical reply within 12 hours, CST working days.