DJYVP-300/500V

DJYVP Instrumentation Cable — Polyethylene Insulated, Overall Braid Screened

PE-insulated pairs under one copper braid screen, for analogue and digital runs of a single signal class.

  • Lead time15–25 working days
  • Minimum500 m per size
  • SampleFree up to 5 m
Illustrative cross section. Construction layers listed below.

Read the code from left to right: D marks the electronic computer and instrumentation family, Y is polyethylene insulation, V is the PVC sheath, and the P written after the sheath letter means the copper wire braid sits over the whole laid-up bundle. That overall screen is the economical choice when every pair in the cable carries the same class of signal — a rack of 4–20 mA loops leaving a control room, or a single digital bus to a remote I/O panel.

Polyethylene is not an incidental detail. With a dielectric constant near 2.3 against roughly 4–6 for PVC, it holds mutual capacitance to about 60 pF/m at 0.5 mm², which is what keeps a 4–20 mA loop within its transmitter load limit and lets an RS-485 segment reach its rated distance. Voltcore twists each pair at a lay length of 40–70 mm, chosen so that consecutive pairs do not share a repeating beat and crosstalk does not accumulate.

Specification

DJYVP 300/500 V — Technical Specification
ItemValue
Rated voltage U0/U300/500 V
ConductorClass 2 stranded plain annealed copper, IEC 60228 (Class 1 solid on request)
Number of pairs1 – 24
Cross-section range0.5 – 2.5 mm²
InsulationPolyethylene (PE), dielectric constant ≈ 2.3
Pair twistingLay length 40–70 mm, varied between adjacent pairs
ScreenCopper wire braid over the bundle, 80–90 % coverage, with tinned drain wire
SheathPVC black; blue for intrinsically safe circuits; LSZH on request
Mutual capacitance at 1 kHz≤ 60–85 pF/m depending on cross-section
Max. continuous conductor temperature70 °C
Test voltage2 kV rms for 5 min (core to core), 1 kV rms (core to screen)
Minimum bending radius10 × cable overall diameter

Layer-by-layer construction

Listed from the conductor outward. Read this alongside the specification table — the two together tell you whether the cable will survive its installation method.

  1. 1. ConductorStranded plain annealed copper, Class 2 to IEC 60228, 7-wire construction
  2. 2. InsulationPolyethylene extruded per core at 0.5–0.7 mm wall, colour coded to the pair identification scheme
  3. 3. Pair twistingTwo insulated cores twisted with a lay length of 40–70 mm, varied between adjacent pairs
  4. 4. Lay-up and binderPairs cabled in concentric layers with fillers and a polyester binder tape over the bundle
  5. 5. ScreenCopper wire braid at 80–90 % coverage with a tinned copper drain wire in continuous contact
  6. 6. SheathPVC black, 1.2–1.8 mm nominal; blue sheath available for intrinsically safe circuits

Reference dimensions and weights

DJYVP 300/500 V — 4-pair dimensions and weight (reference figures)
Pairs × cross-section (mm²)Conductor structure (No./mm)Insulation thickness (mm)Pair lay length (mm)Approx. overall diameter (mm)Approx. weight (kg/km)Max. DC resistance at 20 °C (Ω/km)Mutual capacitance at 1 kHz (pF/m)
4×2×0.57/0.300.54511.218036.0≤ 60
4×2×0.757/0.370.55012.423224.5≤ 65
4×2×1.07/0.430.65513.829218.1≤ 70
4×2×1.57/0.520.66015.337512.1≤ 75
4×2×2.57/0.680.77018.15407.41≤ 85

Reference figures for preliminary sizing and drum planning. Overall diameter and weight vary with strand construction and sheath thickness tolerance; certified drawings are issued with each quotation.

Engineering characteristics

  • Polyethylene insulation holds mutual capacitance to ≤ 60–85 pF/m, roughly half the value of a PVC pair
  • Pairs twisted at 40–70 mm lay length with the length varied between pairs to suppress crosstalk buildup
  • Copper wire braid at 80–90 % coverage over the whole bundle with a tinned drain wire
  • 300/500 V rating, 2 kV rms core to core and 1 kV rms core to screen for 5 min
  • 1 to 24 pairs in 0.5–2.5 mm², so one cable can serve an entire remote I/O drop
  • Blue sheath option to identify intrinsically safe circuits to IEC 60079-14 practice
  • Minimum bending radius 10 × overall diameter, which suits dense marshalling racks

Typical applications

  • 4–20 mA analogue loops between field transmitters and a control room marshalling panel
  • Remote I/O drops where all pairs carry the same signal class
  • Digital telemetering between RTUs and SCADA master stations
  • Analogue and pulse wiring inside analyser houses and metering panels
  • Level, pressure and flow transmitter homeruns on water and chemical plant

Ordering options

  • DJYPVP: individual pair screens in addition to the overall braid
  • Blue PVC sheath for intrinsically safe circuit identification
  • LSZH sheath to IEC 60754-1 and IEC 61034-2
  • Class 1 solid conductors for fixed installation, or Class 5 for flexible connections
  • Steel tape or steel wire armour (DJYVP22, DJYVP32) for burial and outdoor runs

Standards manufactured to

  • GB/T 9330 (construction and test practice)
  • IEC 60228 (conductor)
  • GB/T 19666 (flame-retardant grades)
  • IEC 60332-1-2 (flame propagation)
  • IEC 60079-14 (installation of intrinsically safe circuits)
  • RoHS and REACH compliant compounds

Manufactured to other standards on request. Send the standard number with your RFQ and we will quote against it rather than against a near-equivalent.

Price and availability for DJYVP Overall Screened Instrumentation Cable

Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.

  • Engineer-reviewed before pricing
  • Reference drawings issued with the quotation
  • Free sample up to free sample up to 5 m

or sales@cable-export-manufacture.com · WhatsApp

DJYVP Overall Screened Instrumentation Cable — frequently asked questions

Is DJYVP the same as DJYPVP?

No. In the GB type code the shield letter before the sheath letter V means individual pair screens, and the letter after V means an overall screen. DJYVP therefore carries one braid over the whole bundle; DJYPVP carries a braid over each pair plus a braid over the bundle.

Why polyethylene insulation instead of PVC on an instrumentation pair?

Capacitance. PE has a dielectric constant near 2.3 against roughly 4–6 for PVC, which holds mutual capacitance to about 60 pF/m against 90–130 pF/m. That keeps the loop inside the transmitter load limit and lets long RS-485 segments reach their rated distance.

Can I put a 24 V DC switching circuit and a 4–20 mA pair in one DJYVP cable?

It is poor practice. The overall braid stops interference entering the cable but not interference generated inside it, so a switched inductive load will induce spikes into the analogue pair. Use DJYPVP with individual pair screens, or run the switching circuit in a separate cable.

What pair counts are available and how is the pair identified?

Voltcore supplies 1 to 24 pairs in 0.5–2.5 mm². Pairs are identified by colour combination to a standard sequence, with numbered tape or printed numbering above roughly 10 pairs so that termination crews can identify a pair without tracing it.

Tell us the load, the route and the standard — we will come back with a sized quotation

RFQs are answered by an application engineer first. Typical reply within 12 hours, CST working days.