RVVP Flexible Shielded Cable
RVVP-300/300V
Fine-wire flexible screened cable for panel wiring, machine interfaces and short signal runs.
A screen does one job: it gives interference a low-impedance path to earth that does not pass through the signal conductor. How well it does that job is measured by transfer impeda
A screen does one job: it gives interference a low-impedance path to earth that does not pass through the signal conductor. How well it does that job is measured by transfer impedance, in milliohms per metre, and that figure depends on two things engineers often conflate — the optical coverage of the screen and the resistance of the path along it. Coverage governs leakage at high frequency; resistance governs behaviour at power frequency and at the switching frequencies a drive produces.
This is why the four constructions here exist side by side. RVVP is a light flexible screened cable for panel and machine wiring, LIYCY is the European equivalent with fine-wire conductors and VDE-recognised construction, KVVRP is a flexible braid-screened control cable at 450/750 V, and the overall screened twisted pair is the EMC-grade construction for panels that carry millivolt signals next to contactors.
RVVP-300/300V
Fine-wire flexible screened cable for panel wiring, machine interfaces and short signal runs.
LIYCY-250V
The European screened data cable: fine-wire cores, tinned copper braid, VDE-recognised construction.
KVVRP-450/750V
Class 5 conductors inside a copper braid screen, for screened circuits that move.
OS-TP-300/500V
Foil for coverage, braid for the return path — the construction panels need next to drives.
A variable frequency drive switches several hundred volts in tens of nanoseconds. That dV/dt drives a common-mode current through the parasitic capacitance between the motor conductors and earth, and the current returns to the drive through whatever path it can find — the motor earth, the cable tray, or the screen of a nearby signal cable. Left uncontrolled, it raises bearing currents and pushes radiated emissions past the limits of IEC 61800-3.
A screened motor cable gives that current a defined return path inside the cable, so it does not travel through the installation. The screen must be a braid rather than a foil, because at the carrier frequency the deciding factor is shield resistance, and it must be terminated 360° at both ends with a metal gland or a clamp.
An unshielded 4–20 mA pair running parallel to a 400 A feeder picks up both capacitively coupled voltage and inductively coupled current. Coupled voltage divides down across the loop impedances and appears as common-mode error; coupled current flows in the loop and adds directly to the measured value. Screened cable removes the first almost entirely and reduces the second by the ratio of the shield transfer impedance to the loop impedance.
Earthing practice then decides whether the remaining error matters. Earth the pair screen at one end for a pure analogue loop so no ground-loop current circulates; earth it at both ends only where the installation has a bonded earth plane and the cable passes through an area of high-frequency interference.
The best screen is undone by a bad termination. A drain wire twisted into a pigtail adds roughly 10–20 nH, which is enough to raise the impedance of the termination path above the impedance of the interference source at a few hundred kilohertz, so the screen stops working exactly where it is needed most.
Use an EMC cable gland, a metal screen clamp on a grounded rail, or a conductive backshell on a connector, all of which hold the braid against metal around the full circumference. Strip only as much sheath as the termination needs, and keep the exposed drain wire under 25 mm.
Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.
RFQs are answered by an application engineer first. Typical reply within 12 hours, CST working days.