CKYJP-0.6/1kV

Marine Flame Retardant Low Smoke Control & Instrumentation Cable

Screened control and instrumentation cable that keeps signal integrity beside power runs.

  • Lead time15–25 working days
  • Minimum500 m per size
  • SampleFree up to 5 m
Illustrative cross section. Construction layers listed below.

Control and instrumentation cable on a ship carries the signals that keep machinery under control: alarm and monitoring loops, valve and pump commands, navigation and communication interfaces. IEC 60092-376 covers these cables at 150/250 V, and Voltcore also supplies 0.6/1 kV versions where control circuits share a voltage level with power. The build is stranded tinned copper, halogen-free insulation and sheath, and a screen on each pair or over the whole assembly.

Cross-talk is the practical problem, not current capacity. A control cable bundled beside a 95 mm² power cable picks up enough interference to trigger false alarms, so the screen and its drain wire matter more than the conductor size. Voltcore supplies individual pair screens for analogue 4–20 mA loops and a collective screen for digital signals, with braid coverage and drain wire size stated on the datasheet and SHF2 sheath as standard.

Specification

Marine control and instrumentation cable 150/250 V and 0.6/1 kV — Technical Specification
ItemValue
Rated voltage U0/U150/250 V instrumentation; 0.6/1 kV control
ConductorStranded tinned copper, Class 2 or Class 5, IEC 60228
InsulationHalogen-free cross-linked polyolefin, 90 °C, IEC 60092-360
ScreeningAluminium-polyester tape with tinned drain wire per pair, or collective copper braid
Braid coverage80% minimum for tinned copper wire braid
SheathSHF2 halogen-free thermosetting polyolefin, IEC 60092-359
Flame retardanceIEC 60332-1 single cable; IEC 60332-3-22 category A bunched
Smoke and acidityIEC 61034-2 ≥ 60% transmittance; IEC 60754-1 ≤ 5 mg/g
Core count and sizes2 to 37 cores in 0.75, 1, 1.5 and 2.5 mm²
Min bending radius6 × OD fixed, 8 × OD where flexed
Designed and tested toIEC 60092-350, IEC 60092-376, IEC 60092-359, IEC 60092-360

Layer-by-layer construction

Listed from the conductor outward. Read this alongside the specification table — the two together tell you whether the cable will survive its installation method.

  1. 1. ConductorStranded tinned copper, Class 2 or Class 5, IEC 60228
  2. 2. InsulationHalogen-free cross-linked polyolefin, 90 °C, colour or number coded, IEC 60092-360
  3. 3. Pair or core lay-upCores laid in pairs, triples or bundles with a tinned drain wire in contact with the screen
  4. 4. ScreenAluminium-polyester tape per pair, or collective tinned copper wire braid at 80% minimum coverage
  5. 5. BeddingHalogen-free bedding compound over the screened assembly
  6. 6. Outer sheathSHF2 thermosetting halogen-free polyolefin, IEC 60092-359, black or grey

Reference dimensions and weights

Marine control cable — screened multi-core reference dimensions and weight
Cores × cross-section (mm²)Conductor structure (n × mm)Insulation thickness (mm)ScreenApprox. overall diameter (mm)Approx. weight (kg/km)
2 × 1.57 / 0.520.6Al/PET tape + 0.5 mm² tinned drain wire10.6175
4 × 1.57 / 0.520.6Al/PET tape + 0.5 mm² tinned drain wire12.4260
4 × 2.57 / 0.670.7Al/PET tape + 0.5 mm² tinned drain wire13.9340
7 × 1.57 / 0.520.6Al/PET tape + 0.5 mm² tinned drain wire14.9400
7 × 2.57 / 0.670.7Al/PET tape + 0.5 mm² tinned drain wire16.4520
12 × 1.57 / 0.520.6Al/PET tape + 0.5 mm² tinned drain wire18.4640
12 × 2.57 / 0.670.7Al/PET tape + 0.5 mm² tinned drain wire20.8850
19 × 1.57 / 0.520.6Al/PET tape + 0.5 mm² tinned drain wire22.2950
19 × 2.57 / 0.670.7Al/PET tape + 0.5 mm² tinned drain wire25.01250
24 × 2.57 / 0.670.7Al/PET tape + 0.5 mm² tinned drain wire28.41550

Reference figures for preliminary sizing and drum planning. Overall diameter and weight vary with strand construction and sheath thickness tolerance; certified drawings are issued with each quotation.

Engineering characteristics

  • Individual pair screening with a tinned drain wire keeps 4–20 mA analogue loops clean where they share a tray with power cable.
  • Collective tinned copper braid at 80% coverage suits digital and communication circuits where one screen over the bundle is enough.
  • SHF2 halogen-free thermosetting sheath to IEC 60092-359 with acid gas not above 5 mg/g and transmittance not below 60%.
  • Stranded tinned copper keeps crimped and spring-terminal connections stable in salt-laden humidity.
  • Bunched flame retardance to IEC 60332-3-22 category A, the category shipbuilding specifications normally cite for grouped runs.
  • Core identification by printed number plus colour, so a 24-core loop can be terminated without a continuity sweep.
  • Supplied from 2 to 37 cores in 0.75 to 2.5 mm², covering alarm, monitoring, valve control and navigation interfaces.

Typical applications

  • Engine room alarm and monitoring systems
  • Valve, pump and fan remote control circuits
  • Navigation, radar and communication interfaces
  • Cargo pump and ballast system control on tankers
  • Offshore platform process control and shutdown systems
  • HVAC and fire damper control in accommodation spaces

Ordering options

  • Individually screened pairs, collectively screened, or both
  • Collective tinned copper braid at 80% coverage for higher interference environments
  • Steel wire braid armour with an inner sheath for exposed deck routes
  • 0.75 mm² and 1 mm² instrumentation cores, or 1.5 to 2.5 mm² control cores
  • Numbered and coloured core identification with printed sheath legend and metre marking

Standards manufactured to

  • IEC 60092-350
  • IEC 60092-376
  • IEC 60092-359
  • IEC 60092-360
  • IEC 60332-3-22
  • IEC 60754-1
  • IEC 61034-2
  • IEC 60228

Manufactured to other standards on request. Send the standard number with your RFQ and we will quote against it rather than against a near-equivalent.

Price and availability for Marine Flame Retardant Low Smoke Control Cable

Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.

  • Engineer-reviewed before pricing
  • Reference drawings issued with the quotation
  • Free sample up to free sample up to 5 m

or sales@cable-export-manufacture.com · WhatsApp

Marine Flame Retardant Low Smoke Control Cable — frequently asked questions

Do I need individual pair screens or one collective screen?

Individual screens for analogue 4–20 mA loops and where pairs carry different signal types, because they stop one loop coupling into another. A collective screen is enough for digital buses and switching circuits. Where the cable runs beside variable-speed drive output, specify both: pair screens plus an overall braid.

Can control cable share a tray with power cable?

Yes, with segregation to the applicable installation rules and with screened cable. Keep analogue and digital circuits apart, run the shortest parallel length possible and cross power cables at right angles. Earth the drain wire at one end only, normally the panel end, so that a screen does not become a path for circulating current.

Do you supply 150/250 V instrumentation cable to IEC 60092-376?

Yes, in 0.75 mm² and 1 mm² with individually screened pairs or triples and an overall braid. Instrumentation versions to the NEK 606 S101 to S104 types, with mud-resistant SHF2 sheath, are supplied for offshore modules on request.

What conductor size should I use on a long alarm loop?

Work from loop resistance rather than current. 0.75 mm² is fine up to roughly 80 m; beyond about 100 m move to 1.5 mm² and check the total loop resistance against the monitoring input threshold, because a marginal loop gives intermittent alarms that are hard to trace.

Tell us the load, the route and the standard — we will come back with a sized quotation

RFQs are answered by an application engineer first. Typical reply within 12 hours, CST working days.