BV-450/750V

BV Single-Core Rigid Copper Building Wire, 450/750 V

The 450/750 V rigid copper wire that IEC-aligned projects name on the drawing, in every colour an electrician asks for.

  • Lead time15–25 working days
  • Minimum500 m per size
  • SampleFree up to 5 m
Illustrative cross section. Construction layers listed below.

BV is the default wire on GB/T and IEC-aligned projects: a single core, a rigid copper conductor, and a PVC/C compound over it, rated 450/750 V. The word rigid matters. Up to 6 mm² the conductor is a single solid wire of Class 1, which holds its shape when it is dressed into a board and gives a gas-tight termination under a screw terminal. Above 6 mm² it moves to Class 2 stranding, because a solid 35 mm² conductor cannot be pulled or bent at all.

The compound does the rest of the work. PVC/C is rated for a 70 °C continuous conductor temperature, which is the basis of the current ratings in the GB/T 5023 and IEC 60227 tables, and it is produced in the full range of colours a wiring regulation demands. Voltcore supplies BV from 1.5 mm² to 400 mm² in 100 m coils, and marks the coil with the size, the voltage and the standard.

Specification

BV 450/750 V — technical specification
ItemValue
Rated voltage U0/U450/750 V
ConductorClass 1 solid copper to 6 mm², Class 2 stranded from 10 mm², IEC 60228
Cross-section range1.5 – 400 mm²
Number of cores1
InsulationPVC/C compound, 0.7–2.4 mm nominal by size
Maximum conductor temperature+70 °C continuous
Short-circuit temperature160 °C for 5 s
Minimum installation temperature0 °C
Minimum bending radius4 × overall diameter
Voltage test2.5 kV AC for 5 min in water
Flame behaviourIEC 60332-1-2
StandardGB/T 5023.3, IEC 60227-3

Layer-by-layer construction

Listed from the conductor outward. Read this alongside the specification table — the two together tell you whether the cable will survive its installation method.

  1. 1. ConductorClass 1 solid annealed copper to 6 mm², Class 2 stranded from 10 mm², to IEC 60228
  2. 2. InsulationPVC/C compound, 0.7–2.4 mm nominal wall, circular and concentric, coloured
  3. 3. Surface and markingSmooth finish with printed marking at intervals: GB/T 5023.3, BV, size, voltage rating
  4. 4. Package100 m coils as standard, shrink-wrapped and labelled, or drums for larger sizes

Reference dimensions and weights

BV 450/750 V — reference dimensions, weight, resistance and current rating
Nominal cross-section (mm²)Conductor structure (n×mm)Insulation thickness (mm)Approx. overall diameter (mm)Approx. weight (kg/km)Max. DC resistance at 20 °C (Ω/km)Current rating in conduit at 30 °C (A)
1.51 × 1.380.72.920.312.115.5
2.51 × 1.780.83.531.57.4121
41 × 2.250.84.045.54.6128
61 × 2.760.84.563.03.0836
107 × 1.351.06.01101.8350
167 × 1.701.07.11631.1568
257 × 2.141.28.82540.72789
357 × 2.521.210.03430.524111

Reference figures for preliminary sizing and drum planning. Overall diameter and weight vary with strand construction and sheath thickness tolerance; certified drawings are issued with each quotation.

Engineering characteristics

  • 450/750 V rating to GB/T 5023.3 and IEC 60227, which is the voltage class IEC projects specify.
  • Solid Class 1 conductor to 6 mm², so a termination under a screw terminal stays gas-tight.
  • 70 °C continuous conductor temperature and 160 °C for 5 s short-circuit rating on the PVC/C compound.
  • Insulation wall from 0.7 mm to 2.4 mm, tabulated per size, which is what a voltage test at 2.5 kV confirms.
  • Resistance and current rating tabulated per size, for a drop calculation on a long final circuit.
  • Produced in the full colour range, including green-yellow for protective earth.
  • Resistance figures are for plain annealed copper to IEC 60228, the highest-conductivity option.

Typical applications

  • Fixed wiring inside conduit and trunking in buildings
  • Power and lighting final circuits in housing and commercial units
  • Distribution board internal wiring
  • Clipped direct runs on joists and walls inside a building
  • Control panel and switchgear internal wiring
  • Machine tool and equipment internal wiring

Ordering options

  • 1.5–400 mm² in 100 m coils or on drums
  • Full colour range: brown, blue, black, grey, red, green-yellow, yellow, white
  • Solid Class 1 up to 6 mm², Class 2 stranded from 10 mm²
  • Tinned copper conductor for humid and coastal projects
  • Private-label coil labels and OEM printing for distributors

Standards manufactured to

  • GB/T 5023.3
  • IEC 60227-3
  • IEC 60228
  • IEC 60332-1-2
  • CCC

Manufactured to other standards on request. Send the standard number with your RFQ and we will quote against it rather than against a near-equivalent.

Price and availability for BV Single-Core Rigid Copper PVC Building Wire

Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.

  • Engineer-reviewed before pricing
  • Reference drawings issued with the quotation
  • Free sample up to free sample up to 5 m

or sales@cable-export-manufacture.com · WhatsApp

BV Single-Core Rigid Copper PVC Building Wire — frequently asked questions

Can I use BV where the project calls for THHN?

Not as a straight substitution. BV is rated 450/750 V to GB/T 5023 and has a single PVC wall with no nylon jacket. THHN is rated 600 V to UL 83 and carries that nylon jacket, which is what survives a pull through metal conduit. On an NEC project the inspector looks for the UL listing mark and the THHN/THWN-2 print, and BV does not carry them.

Why is BV solid up to 6 mm² and stranded above?

Handling. A solid 10 mm² or 25 mm² conductor is too stiff to bend into a terminal or pull through a bend, so GB/T 5023.3 moves to Class 2 stranded from 10 mm² upwards. Below that, the solid conductor is the better choice: it holds its shape when dressed and makes a tighter termination under a screw.

What colours do you keep in stock?

Brown, blue, black, grey, red, yellow, white and green-yellow, which covers the phase, neutral and protective earth functions a wiring regulation asks for. Green-yellow is produced to the bi-colour requirement for protective conductors. Colours outside the standard range are made to order on volume, with the standard 500 m minimum per size.

What is the current rating I should design to?

Use the tabulated rating for the installation method, not the free-air figure. The values in the size table are for three loaded conductors in conduit at 30 °C ambient, which is the common case in a building. For more than three loaded cores in one conduit, or for an ambient above 30 °C, apply the group and temperature derating factors from the wiring regulation you work to.

Tell us the load, the route and the standard — we will come back with a sized quotation

RFQs are answered by an application engineer first. Typical reply within 12 hours, CST working days.