KVVR-450/750V

KVVR Flexible PVC Control Cable — Class 5 Conductors, 450/750 V

Class 5 fine-wire conductors for control circuits that move, bend or vibrate.

  • Lead time15–25 working days
  • Minimum500 m per size
  • SampleFree up to 5 m
Illustrative cross section. Construction layers listed below.

The R in KVVR marks flexible construction: instead of the 7-wire Class 2 conductor used in KVV, each core is built from fine wires — 16/0.20 at 0.5 mm² up to 56/0.30 at 4 mm² — to IEC 60228 Class 5. That changes the mechanical behaviour rather than the electrical rating: the cable still works at 450/750 V with the same 70 °C PVC insulation, but it tolerates bending radii down to 6 × overall diameter and repeated flexing in machine-mounted service.

Specify KVVR where the wiring is terminated on something that moves: machine tool carriages, control pendants, cubicle door harnesses, vibrating pump skids. Voltcore bunches the conductors with a short lay length so the strands share the strain rather than the outer layer taking it all, and the sheath compound is plasticised for low-temperature flexibility; below 0 °C the cable must be warmed before installation.

Specification

KVVR 450/750 V — Technical Specification
ItemValue
Rated voltage U0/U450/750 V
ConductorClass 5 flexible plain annealed copper, IEC 60228
Number of cores2 – 61
Cross-section range0.5 – 4 mm²
InsulationPVC/A flexible grade, 70 °C rated
SheathFlexible PVC, black, grey to special order
Max. continuous conductor temperature70 °C
Short-circuit conductor temperature160 °C for 5 s maximum
Test voltage2.5 kV rms for 5 min, no breakdown
Minimum bending radius6 × cable overall diameter in moving service
Installation temperatureNot below 0 °C; warm the cable before handling below 5 °C
Core identificationNumbered print or colour coded

Layer-by-layer construction

Listed from the conductor outward. Read this alongside the specification table — the two together tell you whether the cable will survive its installation method.

  1. 1. ConductorBunched fine-wire plain annealed copper, Class 5 to IEC 60228, 0.20–0.30 mm single wire
  2. 2. InsulationFlexible PVC/A extruded per core, 0.6–0.8 mm wall
  3. 3. Lay-upCores stranded in concentric layers with a short lay length for flexibility
  4. 4. FillerNon-hygroscopic filler or a central filler cord to maintain a circular section
  5. 5. BinderLight polyester or non-woven tape over the bundle, allowing layers to slide against each other
  6. 6. SheathFlexible PVC black, 1.0–1.4 mm nominal, plasticised for low-temperature handling

Reference dimensions and weights

KVVR 450/750 V — 4-core dimensions and weight (reference figures)
Cores × cross-section (mm²)Conductor structure (No./mm)Insulation thickness (mm)Sheath thickness (mm)Approx. overall diameter (mm)Approx. weight (kg/km)Max. DC resistance at 20 °C (Ω/km)
4×0.516/0.200.61.06.88239.0
4×0.7524/0.200.61.07.410426.0
4×1.032/0.200.61.07.812219.5
4×1.530/0.250.71.28.916813.3
4×2.550/0.250.71.210.42427.98
4×456/0.300.81.412.33484.95

Reference figures for preliminary sizing and drum planning. Overall diameter and weight vary with strand construction and sheath thickness tolerance; certified drawings are issued with each quotation.

Engineering characteristics

  • Class 5 conductors of 0.20–0.30 mm wires give a bending radius of 6 × overall diameter
  • Flexible sheath compound rated 70 °C continuous and 160 °C for 5 s short circuit
  • 450/750 V rating with 2.5 kV rms for 5 min test voltage
  • Higher DC resistance than Class 2 at the same nominal section, so check voltage drop on long runs
  • Short lay length bunching distributes bending strain across the strand instead of the outer layer
  • Available in 2 to 61 cores from 0.5 mm² to 4 mm²
  • ZR-KVVR flame-retardant sheath to GB/T 19666 for machine enclosures

Typical applications

  • Machine tool control wiring on carriages, turrets and moving heads
  • Cubicle and control desk door harnesses that open repeatedly
  • Pendant stations, handheld control boxes and portable test sets
  • Vibrating equipment: pump skids, screens, compressors and fan housings
  • Appliance and panel builder harnesses where tight bends are unavoidable

Ordering options

  • ZR-KVVR flame-retardant sheath to GB/T 19666
  • KVVRP: adds a copper wire braid screen for flexible screened circuits
  • Tinned Class 5 conductors for humid or coastal installations
  • Grey, orange or customer-specified sheath colour for identification on a machine
  • Cut-to-length harness sets with printed ferrule marking and bagged kits

Standards manufactured to

  • GB/T 9330
  • IEC 60228 Class 5 (conductor)
  • GB/T 19666 (flame-retardant grades)
  • IEC 60332-1-2 (flame propagation)
  • RoHS and REACH compliant compounds

Manufactured to other standards on request. Send the standard number with your RFQ and we will quote against it rather than against a near-equivalent.

Price and availability for KVVR Flexible Control Cable

Include cross-section, core count, voltage grade, route length and installation method — those five determine price more than anything else on the page.

  • Engineer-reviewed before pricing
  • Reference drawings issued with the quotation
  • Free sample up to free sample up to 5 m

or sales@cable-export-manufacture.com · WhatsApp

KVVR Flexible Control Cable — frequently asked questions

What is the practical difference between KVV and KVVR?

KVV uses Class 2 conductors and is installed once; KVVR uses Class 5 fine-wire conductors and tolerates repeated bending. Electrically they are both 450/750 V with 70 °C PVC, but KVVR has a slightly higher DC resistance at the same nominal section and costs more per metre.

Can KVVR be used in a drag chain?

It is suitable for occasional flexing and moderate bending cycles, not for continuous high-speed cable carrier duty. For a drag chain running millions of cycles, specify a purpose-built PUR-sheathed chain cable; Voltcore will quote that separately.

Why is the DC resistance of KVVR higher than KVV at 1.5 mm²?

Class 5 stranding uses many fine wires with a short lay length measured along the helical path, so the effective conductor length per metre of cable is slightly greater. The IEC 60228 limit is 13.3 Ω/km for Class 5 against 12.1 Ω/km for Class 2.

Is KVVR oil resistant?

Standard PVC sheath resists mineral oil splash but not continuous immersion. For machine tools with cutting-oil exposure, ask for an oil-resistant PVC/PUR sheath variant; Voltcore supplies it with a modified compound and confirms the rating on the datasheet.

Tell us the load, the route and the standard — we will come back with a sized quotation